听力与言语-语言病理学

行为科学

医学伦理学

你正在浏览MAGNETIC RESONANCE IN MEDICINE期刊下所有文献
  • PRESTO-SENSE: an ultrafast whole-brain fMRI technique.

    abstract::A new ultrafast MR imaging method is proposed and tested, which enables whole-brain fMRI with a true temporal resolution of 1 sec. The method combines a 3D PRESTO pulse sequence with the concept of sensitivity-encoding with multiple receiver coils (SENSE). The so-called PRESTO-SENSE technique is demonstrated on a set ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/1522-2594(200006)43:6<779::aid-mrm1>3.0.co

    authors: Golay X,Pruessmann KP,Weiger M,Crelier GR,Folkers PJ,Kollias SS,Boesiger P

    更新日期:2000-06-01 00:00:00

  • Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling.

    abstract::Perfusion imaging by arterial spin labeling (ASL) can be highly sensitive to the transit time from the labeling site to the tissue. We report the results of a study designed to separate the transit time and perfusion contributions to activation in ASL images accompanying motor and visual stimulation. Fractional transi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200005)43:5<739::aid-mrm17

    authors: Gonzalez-At JB,Alsop DC,Detre JA

    更新日期:2000-05-01 00:00:00

  • 1H and (31)P magnetization transfer studies of hindleg muscle in wild-type and creatine kinase-deficient mice.

    abstract::The authors addressed the hypothesis that interactions with creatine kinase (CK) play a role in the off-resonance magnetization transfer (MT) effect of creatine in skeletal muscle. Toward that aim, (1)H MT studies were done on hindleg muscle in wild-type mice and in transgenic mice, lacking cytoplasmic CK and/or mitoc...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200005)43:5<657::aid-mrm7>

    authors: Kruiskamp MJ,van Vliet G,Nicolay K

    更新日期:2000-05-01 00:00:00

  • Reduction of resonant RF heating in intravascular catheters using coaxial chokes.

    abstract::The incorporation of RF coils into the tips of intravascular devices has been shown to enable the localization of catheters and guidewires under MR guidance. Furthermore, such coils can be used for endoluminal imaging. The long cable required to connect the coil with the scanner input inadvertently acts as a dipole an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200004)43:4<615::aid-mrm19

    authors: Ladd ME,Quick HH

    更新日期:2000-04-01 00:00:00

  • A reduced field-of-view method to increase temporal resolution or reduce scan time in cine MRI.

    abstract::In some dynamic applications of MRI, only a part of the field-of-view (FOV) actually undergoes dynamic changes. A class of methods, called reduced-FOV (rFOV) methods, convert the knowledge that some part of the FOV is static or not very dynamic into an increase in temporal resolution for the dynamic part, or into a re...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200004)43:4<549::aid-mrm9>

    authors: Madore B,Fredrickson JO,Alley MT,Pelc NJ

    更新日期:2000-04-01 00:00:00

  • Prospective multiaxial motion correction for fMRI.

    abstract::Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagit...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200003)43:3<459::aid-mrm19

    authors: Ward HA,Riederer SJ,Grimm RC,Ehman RL,Felmlee JP,Jack CR Jr

    更新日期:2000-03-01 00:00:00

  • Three-dimensional whole body imaging of spin probes in mice by time-domain radiofrequency electron paramagnetic resonance.

    abstract::Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom obj...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>

    authors: Afeworki M,van Dam GM,Devasahayam N,Murugesan R,Cook J,Coffin D,Larsen JH,Mitchell JB,Subramanian S,Krishna MC

    更新日期:2000-03-01 00:00:00

  • Functional magnetic resonance imaging in real time (FIRE): sliding-window correlation analysis and reference-vector optimization.

    abstract::New algorithms for correlation analysis are presented that allow the mapping of brain activity from functional MRI (fMRI) data in real time during the ongoing scan. They combine the computation of the correlation coefficients between measured fMRI time-series data and a reference vector with "detrending", a technique ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<259::aid-mrm13

    authors: Gembris D,Taylor JG,Schor S,Frings W,Suter D,Posse S

    更新日期:2000-02-01 00:00:00

  • Cardiac real-time imaging using SENSE. SENSitivity Encoding scheme.

    abstract::Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>

    authors: Weiger M,Pruessmann KP,Boesiger P

    更新日期:2000-02-01 00:00:00

  • Diffusion imaging of the spinal cord in vivo: estimation of the principal diffusivities and application to multiple sclerosis.

    abstract::Magnetic resonance (MR) diffusion imaging is a useful technique with which to increase our understanding of pathologic damage to the central nervous system. To fully quantitate diffusion and anisotropy in the spinal cord, as in other tissues, it is necessary to determine the diffusion tensor. If spinal cord diffusion ...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<133::aid-mrm16

    authors: Clark CA,Werring DJ,Miller DH

    更新日期:2000-01-01 00:00:00

  • Cocaine administration decreases functional connectivity in human primary visual and motor cortex as detected by functional MRI.

    abstract::Functional magnetic resonance imaging (fMRI) was conducted to observe the effects of cocaine administration on the physiological fluctuations of fMRI signal in two brain regions. Seven long-term cocaine users with an average age of 32 years and 8 years of cocaine use history were recruited for the study. A T2*-weighte...

    journal_title:Magnetic resonance in medicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/(sici)1522-2594(200001)43:1<45::aid-mrm6>3

    authors: Li SJ,Biswal B,Li Z,Risinger R,Rainey C,Cho JK,Salmeron BJ,Stein EA

    更新日期:2000-01-01 00:00:00

  • Fast multislice T(1) and t(1sat) imaging using a phase acquisition of composite echoes (PACE) technique.

    abstract::An optimized multislice data acquisition scheme for phase acquisition of composite echoes (PACE) imaging is presented. This new scheme uses a repetition time equal to the mixing time and an appropriate phase cycling scheme, which allows for more efficient exploitation of all composite echoes. These modifications provi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199912)42:6<1089::aid-mrm1

    authors: Ropele S,Stollberger R,Kapeller P,Hartung HP,Fazekas F

    更新日期:1999-12-01 00:00:00

  • Perfusion-based event-related functional MRI.

    abstract::Perfusion-based event-related functional MRI was performed by measuring flow-sensitive alternating inversion recovery (FAIR) signal changes during repeated single-trial, short visual stimulation (250 msec). In the visual cortex activation area, the blood flow increases immediately after the stimulus, reaches the maxim...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199912)42:6<1011::aid-mrm3

    authors: Liu HL,Gao JH

    更新日期:1999-12-01 00:00:00

  • Water diffusion, T(2), and compartmentation in frog sciatic nerve.

    abstract::A potential relationship between structural compartments in neural tissue and NMR parameters may increase the specificity of MRI in diagnosing diseases. Nevertheless, our understanding of MR of nerves and white matter is limited, particularly the influence of various water compartments on the MR signal is not known. I...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199911)42:5<911::aid-mrm11

    authors: Peled S,Cory DG,Raymond SA,Kirschner DA,Jolesz FA

    更新日期:1999-11-01 00:00:00

  • Unaliasing by fourier-encoding the overlaps using the temporal dimension (UNFOLD), applied to cardiac imaging and fMRI.

    abstract::In several applications, MRI is used to monitor the time behavior of the signal in an organ of interest; e.g., signal evolution because of physiological motion, activation, or contrast-agent accumulation. Dynamic applications involve acquiring data in a k-t space, which contains both temporal and spatial information. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>

    authors: Madore B,Glover GH,Pelc NJ

    更新日期:1999-11-01 00:00:00

  • Brain water diffusion in normal and creatine-supplemented rats during transient global ischemia.

    abstract::Brain water diffusion in response to transient global ischemia (12 min), reperfusion (60 min), and cardiac arrest was monitored by localized proton magnetic resonance spectroscopy. The trace of the apparent diffusion coefficient tensor (ADC(Av)) was determined at high temporal resolution (10 sec) to assess the putativ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<798::aid-mrm23

    authors: Wick M,Fujimori H,Michaelis T,Frahm J

    更新日期:1999-10-01 00:00:00

  • An optimized center-out k-space trajectory for multishot MRI: comparison with spiral and projection reconstruction.

    abstract::A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined. It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spir...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<714::aid-mrm13

    authors: Pipe JG

    更新日期:1999-10-01 00:00:00

  • Segmented spin-echo pulses to increase fMRI signal: repeated intrinsic diffusional enhancement.

    abstract::Since its inception, functional magnetic resonance imaging (fMRI) has seen rapid progress in the application to neuroscience. Common gradient-recalled acquisition methods are susceptible to static field inhomogeneities, resulting in signal loss at the medial temporal area important for memory function or at the basal ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199910)42:4<631::aid-mrm3>

    authors: Song AW,Mao H,Muthupillai R,Haist F,Dixon WT

    更新日期:1999-10-01 00:00:00

  • Improved device definition in interventional magnetic resonance imaging using a rotated stripes keyhole acquisition.

    abstract::Keyhole acquisition techniques have been used to reduce image acquisition times primarily in contrast agent studies and via simulation in interventional MRI procedures. More recent simulations have suggested that improved definition of an interventional device [e.g., biopsy needles, radio frequency (RF) electrodes] co...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199909)42:3<554::aid-mrm18

    authors: Hwang KP,Lim J,Wendt M,Merkle E,Lewin JS,Duerk JL

    更新日期:1999-09-01 00:00:00

  • Anisotropic and restricted diffusion of water in the sciatic nerve: A (2)H double-quantum-filtered NMR study.

    abstract::The signals of water in the different compartments of rat sciatic nerve are resolved in the (2)H double-quantum-filtered NMR spectrum, due to their different quadrupolar splittings and relaxation rates. This resolution allowed the independent measurement of the water diffusion coefficients in the different compartment...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199909)42:3<461::aid-mrm8>

    authors: Seo Y,Shinar H,Morita Y,Navon G

    更新日期:1999-09-01 00:00:00

  • Intimate combination of low- and high-resolution image data: I. Real-space PET and (1)H(2)O MRI, PETAMRI.

    abstract::Two different types of (co-registered) images of the same slice of tissue will generally have different spatial resolutions. The judicious pixel-by-pixel combination of their data can be accomplished to yield a single image exhibiting properties of both. Here, axial (18)FDG PET and (1)H(2)O MR images of the human brai...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199908)42:2<345::aid-mrm17

    authors: Sammi MK,Felder CA,Fowler JS,Lee JH,Levy AV,Li X,Logan J,Pályka I,Rooney WD,Volkow ND,Wang GJ,Springer CS Jr

    更新日期:1999-08-01 00:00:00

  • Dynamic imaging of perfusion in human skeletal muscle during exercise with arterial spin labeling.

    abstract::MR images acquired by using an arterial spin-labeling technique showed spatial and temporal variations of perfusion in the skeletal muscle of exercising humans. Perfusion measurements made during plantar flexion exercise in normal volunteers were consistent with those obtained by traditional techniques reported in the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199908)42:2<258::aid-mrm7>

    authors: Frank LR,Wong EC,Haseler LJ,Buxton RB

    更新日期:1999-08-01 00:00:00

  • In vivo time course studies of the tissue responses to resorbable polylactic acid implants by means of MRI.

    abstract::Magnetic resonance (MR) imaging and relaxation time measurements of bioresorbable implants made of polylactic acid (PLA), as well as the surrounding tissues, were carried out over a period of 6 months to monitor the implant state and the body's responses, and to determine how these processes are reflected in MR data. ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<210::aid-mrm29

    authors: Stroman PW,Dorvil JC,Marois Y,Poddevin N,Guidoin R

    更新日期:1999-07-01 00:00:00

  • MRI-guided radiofrequency thermal ablation of implanted VX2 liver tumors in a rabbit model: demonstration of feasibility at 0.2 T.

    abstract::Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STI...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19

    authors: Merkle EM,Boll DT,Boaz T,Duerk JL,Chung YC,Jacobs GH,Varnes ME,Lewin JS

    更新日期:1999-07-01 00:00:00

  • Fast lipid-suppressed MR temperature mapping with echo-shifted gradient-echo imaging and spectral-spatial excitation.

    abstract::The water proton resonance frequency (PRF) is temperature dependent and can thus be used for magnetic resonance (MR) thermometry. Since lipid proton resonance frequencies do not depend on temperature, fat suppression is essential for PRF-based temperature mapping. The efficacy of echo-shifted (TE > TR) gradient-echo i...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199907)42:1<53::aid-mrm9>3

    authors: de Zwart JA,Vimeux FC,Delalande C,Canioni P,Moonen CT

    更新日期:1999-07-01 00:00:00

  • Observing curved flow using RUFIS.

    abstract::The rotating ultra-fast imaging sequence (RUFIS) is used to image spins flowing through the curved portion of a 180 degrees U-tube with a circular cross section and a ratio of inner diameter to curvature diameter of 0.41. A velocity-encoding preparation sequence is used with RUFIS to measure quantitatively the axial v...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1258::aid-mrm2

    authors: Gach HM,Lowe IJ

    更新日期:1999-06-01 00:00:00

  • A numerical approach to non-circular birdcage RF coil optimization: verification with a fourth-order coil.

    abstract::It is demonstrated that birdcage resonators, satisfying conditions of quadrature operation and radiofrequency field homogeneity, can be realized in practice on formers of non-circular cross section described by an equation of the form (x/a)n + (y/b)n = 1 where a and b are constants and n > or = 2 is an integer. Using ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1180::aid-mrm1

    authors: Riauka TA,De Zanche NF,Thompson R,Vermeulen FE,Capjack CE,Allen PS

    更新日期:1999-06-01 00:00:00

  • Multislice perfusion and perfusion territory imaging in humans with separate label and image coils.

    abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4

    authors: Zaharchuk G,Ledden PJ,Kwong KK,Reese TG,Rosen BR,Wald LL

    更新日期:1999-06-01 00:00:00

  • Magnetic resonance angiography with hyperpolarized 129Xe dissolved in a lipid emulsion.

    abstract::Hyperpolarized (HP) 129Xe can be dissolved in biologically compatible lipid emulsions while maintaining sufficient polarization for in vivo vascular imaging. For xenon in Intralipid 30%, in vitro spectroscopy at 2 T yielded a chemical shift of 197 +/- 1 ppm with reference to xenon gas, a spin-lattice relaxation time T...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<1058::aid-mrm2

    authors: Möller HE,Chawla MS,Chen XJ,Driehuys B,Hedlund LW,Wheeler CT,Johnson GA

    更新日期:1999-05-01 00:00:00

  • Motion correction in fMRI via registration of individual slices into an anatomical volume.

    abstract::An automated retrospective image registration based on mutual information is adapted to a multislice functional magnetic resonance imaging (fMRI) acquisition protocol to provide accurate motion correction. Motion correction is performed by mapping each slice to an anatomic volume data set acquired in the same fMRI ses...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<964::aid-mrm16

    authors: Kim B,Boes JL,Bland PH,Chenevert TL,Meyer CR

    更新日期:1999-05-01 00:00:00

  • Localized 1H NMR measurements of 2-pyrrolidinone in human brain in vivo.

    abstract::Localized 1H NMR homonuclear J editing spectroscopy was used to measure the concentration of 2-pyrrolidinone (PRDN) in the human occipital lobe of five normal and six epileptic subjects taking vigabatrin. PRDN is a lactam cyclization product of gamma-aminobutyric acid (GABA). From a localized volume of 13.5 cm3 in the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199905)41:5<889::aid-mrm6>

    authors: Hyder F,Petroff OA,Mattson RH,Rothman DL

    更新日期:1999-05-01 00:00:00

  • 2D multislice and 3D MRI sequences are often equally sensitive.

    abstract::A simple theoretical model was developed to compare the sensitivities (i.e., signal-to-noise ratios per unit imaging time) of two-dimensional (2D) multislice and 3D imaging sequences. The model shows that the sensitivities of 3D and 2D multislice MRI sequences are usually similar. Sensitivities are identical in T2-wei...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<824::aid-mrm23

    authors: Johnson G,Wadghiri YZ,Turnbull DH

    更新日期:1999-04-01 00:00:00

  • In vivo imaging of extracellular pH using 1H MRSI.

    abstract::Tumor pH is physiologically important since it influences a number of processes relevant to tumorigenesis and therapy. Hence, knowledge of localized pH within tumors would contribute to understanding these processes. The destructiveness, poor spatial resolution, and poor signal-to-noise ratio (SNR) of current technolo...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<743::aid-mrm13

    authors: van Sluis R,Bhujwalla ZM,Raghunand N,Ballesteros P,Alvarez J,Cerdán S,Galons JP,Gillies RJ

    更新日期:1999-04-01 00:00:00

  • Concentrations of human cardiac phosphorus metabolites determined by SLOOP 31P NMR spectroscopy.

    abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>

    authors: Meininger M,Landschütz W,Beer M,Seyfarth T,Horn M,Pabst T,Haase A,Hahn D,Neubauer S,von Kienlin M

    更新日期:1999-04-01 00:00:00

  • Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

    abstract::Wavelet packet analysis is a mathematical transformation that can be used to post-process images, for example, to remove image noise ("denoising"). At a very low signal-to-noise ratio (SNR <5), standard magnitude magnetic resonance images have skewed Rician noise statistics that degrade denoising performance. Since th...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<631::aid-mrm29

    authors: Wood JC,Johnson KM

    更新日期:1999-03-01 00:00:00

  • 3D coronary artery imaging with phase reordering for improved scan efficiency.

    abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19

    authors: Jhooti P,Keegan J,Gatehouse PD,Collins S,Rowe A,Taylor AM,Firmin DN

    更新日期:1999-03-01 00:00:00

  • Early changes in water diffusion, perfusion, T1, and T2 during focal cerebral ischemia in the rat studied at 8.5 T.

    abstract::The time evolution of water diffusion, perfusion, T1, and T2 is investigated at high magnetic field (8.5 T) following permanent middle cerebral artery occlusion in the rat. Cerebral blood flow maps were obtained using arterial spin tagging. Although the quantitative perfusion measurements in ischemic tissue still pose...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199903)41:3<479::aid-mrm9>

    authors: Calamante F,Lythgoe MF,Pell GS,Thomas DL,King MD,Busza AL,Sotak CH,Williams SR,Ordidge RJ,Gadian DG

    更新日期:1999-03-01 00:00:00

  • Magnesium and pH imaging of the human brain at 3.0 Tesla.

    abstract::Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calcula...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<400::aid-mrm26

    authors: Barker PB,Butterworth EJ,Boska MD,Nelson J,Welch KM

    更新日期:1999-02-01 00:00:00

  • Quantifying tissue damage due to focused ultrasound heating observed by MRI.

    abstract::Focused ultrasound heating of ex vivo bovine kidney and liver was monitored using magnetic resonance imaging (MRI) to investigate the quantitative relationship between time-dependent temperature elevations and altered contrast in MR images due to thermal coagulation. Proton resonance frequency shift MR thermometry was...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<321::aid-mrm16

    authors: Graham SJ,Chen L,Leitch M,Peters RD,Bronskill MJ,Foster FS,Henkelman RM,Plewes DB

    更新日期:1999-02-01 00:00:00

  • Investigation of the early response to rat forepaw stimulation.

    abstract::The role of relative cerebral blood volume (rCBV) in the early response of blood oxygenation level-dependent (BOLD) signal following sensory stimulation was assessed. Magnetic resonance imaging (MRI) measurements of rCBV and BOLD signal as a function of time (t) were compared with relative cerebral blood flow (rCBF) o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(199902)41:2<247::aid-mrm6>

    authors: Marota JJ,Ayata C,Moskowitz MA,Weisskoff RM,Rosen BR,Mandeville JB

    更新日期:1999-02-01 00:00:00

1170 条记录 22/30 页 « 12...19202122232425...2930 »