解剖学和形态学
麻醉学
听力与言语-语言病理学
行为科学
心脏和心血管系统
细胞和组织工程学
临床神经病学
危重症监护医学
牙科,口腔外科和医学
皮肤病学
急诊医学
内分泌学和新陈代谢
肠胃学和肝脏学
老人病学和老年医学
卫生保健科学和服务
血液学
免疫学
传染病
综合和补充性医学
医学伦理学
医学信息学
医学实验室技术
医学,全科和内科
医学,法律
医学,研究和试验
神经系统科学
护理
营养学和饮食学
产科医学和妇科医学
肿瘤学
眼科学
整形外科学
耳鼻喉科学
病理学
儿科学
周围血管疾病
药理学和药剂学
生理学
基本医疗保健
精神病学
公共、环境和职业卫生
放射学,核医学和医学成像
康复学
生殖生物学
呼吸系统
风湿病学
运动科学
外科学
毒理学
热带医学
泌尿学和肾脏学
病毒学
老年医学
健康政策和服务
心理学,临床
abstract::A new ultrafast MR imaging method is proposed and tested, which enables whole-brain fMRI with a true temporal resolution of 1 sec. The method combines a 3D PRESTO pulse sequence with the concept of sensitivity-encoding with multiple receiver coils (SENSE). The so-called PRESTO-SENSE technique is demonstrated on a set ...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/1522-2594(200006)43:6<779::aid-mrm1>3.0.co
更新日期:2000-06-01 00:00:00
abstract::Perfusion imaging by arterial spin labeling (ASL) can be highly sensitive to the transit time from the labeling site to the tissue. We report the results of a study designed to separate the transit time and perfusion contributions to activation in ASL images accompanying motor and visual stimulation. Fractional transi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200005)43:5<739::aid-mrm17
更新日期:2000-05-01 00:00:00
abstract::The authors addressed the hypothesis that interactions with creatine kinase (CK) play a role in the off-resonance magnetization transfer (MT) effect of creatine in skeletal muscle. Toward that aim, (1)H MT studies were done on hindleg muscle in wild-type mice and in transgenic mice, lacking cytoplasmic CK and/or mitoc...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200005)43:5<657::aid-mrm7>
更新日期:2000-05-01 00:00:00
abstract::The incorporation of RF coils into the tips of intravascular devices has been shown to enable the localization of catheters and guidewires under MR guidance. Furthermore, such coils can be used for endoluminal imaging. The long cable required to connect the coil with the scanner input inadvertently acts as a dipole an...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200004)43:4<615::aid-mrm19
更新日期:2000-04-01 00:00:00
abstract::In some dynamic applications of MRI, only a part of the field-of-view (FOV) actually undergoes dynamic changes. A class of methods, called reduced-FOV (rFOV) methods, convert the knowledge that some part of the FOV is static or not very dynamic into an increase in temporal resolution for the dynamic part, or into a re...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200004)43:4<549::aid-mrm9>
更新日期:2000-04-01 00:00:00
abstract::Corruption of the image time series due to interimage head motion limits the clinical utility of functional MRI. This paper presents a method for real-time prospective correction of rotation and translation in all six degrees of rigid body motion. By incorporating an orbital navigator (ONAV) echo for each of the sagit...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200003)43:3<459::aid-mrm19
更新日期:2000-03-01 00:00:00
abstract::Imaging of stable paramagnetic spin probes in phantom objects and in vivo was evaluated using a RF time domain EPR spectrometer/imager operating at 300 MHz. Projections were collected using static magnetic field gradients and images were reconstructed using filtered back-projection techniques. Results from phantom obj...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200003)43:3<375::aid-mrm9>
更新日期:2000-03-01 00:00:00
abstract::New algorithms for correlation analysis are presented that allow the mapping of brain activity from functional MRI (fMRI) data in real time during the ongoing scan. They combine the computation of the correlation coefficients between measured fMRI time-series data and a reference vector with "detrending", a technique ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200002)43:2<259::aid-mrm13
更新日期:2000-02-01 00:00:00
abstract::Sensitivity encoding is used to improve the performance of real-time MRI. The encoding efficiency of single-shot and segmented echo-planar imaging is tripled by means of a 6-element receiver coil array. The feasibility of this approach is verified for double oblique cardiac real-time imaging of human subjects at rest ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(200002)43:2<177::aid-mrm3>
更新日期:2000-02-01 00:00:00
abstract::Magnetic resonance (MR) diffusion imaging is a useful technique with which to increase our understanding of pathologic damage to the central nervous system. To fully quantitate diffusion and anisotropy in the spinal cord, as in other tissues, it is necessary to determine the diffusion tensor. If spinal cord diffusion ...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/(sici)1522-2594(200001)43:1<133::aid-mrm16
更新日期:2000-01-01 00:00:00
abstract::Functional magnetic resonance imaging (fMRI) was conducted to observe the effects of cocaine administration on the physiological fluctuations of fMRI signal in two brain regions. Seven long-term cocaine users with an average age of 32 years and 8 years of cocaine use history were recruited for the study. A T2*-weighte...
journal_title:Magnetic resonance in medicine
pub_type: 临床试验,杂志文章
doi:10.1002/(sici)1522-2594(200001)43:1<45::aid-mrm6>3
更新日期:2000-01-01 00:00:00
abstract::An optimized multislice data acquisition scheme for phase acquisition of composite echoes (PACE) imaging is presented. This new scheme uses a repetition time equal to the mixing time and an appropriate phase cycling scheme, which allows for more efficient exploitation of all composite echoes. These modifications provi...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199912)42:6<1089::aid-mrm1
更新日期:1999-12-01 00:00:00
abstract::Perfusion-based event-related functional MRI was performed by measuring flow-sensitive alternating inversion recovery (FAIR) signal changes during repeated single-trial, short visual stimulation (250 msec). In the visual cortex activation area, the blood flow increases immediately after the stimulus, reaches the maxim...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199912)42:6<1011::aid-mrm3
更新日期:1999-12-01 00:00:00
abstract::A potential relationship between structural compartments in neural tissue and NMR parameters may increase the specificity of MRI in diagnosing diseases. Nevertheless, our understanding of MR of nerves and white matter is limited, particularly the influence of various water compartments on the MR signal is not known. I...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199911)42:5<911::aid-mrm11
更新日期:1999-11-01 00:00:00
abstract::In several applications, MRI is used to monitor the time behavior of the signal in an organ of interest; e.g., signal evolution because of physiological motion, activation, or contrast-agent accumulation. Dynamic applications involve acquiring data in a k-t space, which contains both temporal and spatial information. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199911)42:5<813::aid-mrm1>
更新日期:1999-11-01 00:00:00
abstract::Brain water diffusion in response to transient global ischemia (12 min), reperfusion (60 min), and cardiac arrest was monitored by localized proton magnetic resonance spectroscopy. The trace of the apparent diffusion coefficient tensor (ADC(Av)) was determined at high temporal resolution (10 sec) to assess the putativ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199910)42:4<798::aid-mrm23
更新日期:1999-10-01 00:00:00
abstract::A method for collecting MRI data on a set of rotated trajectories that begin at the center of k-space is outlined. It is theoretically slightly faster, slightly less susceptible to off-resonance and motion-induced phase, and produces images with slightly better signal-to-noise ratio than methods using Archimedean spir...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199910)42:4<714::aid-mrm13
更新日期:1999-10-01 00:00:00
abstract::Since its inception, functional magnetic resonance imaging (fMRI) has seen rapid progress in the application to neuroscience. Common gradient-recalled acquisition methods are susceptible to static field inhomogeneities, resulting in signal loss at the medial temporal area important for memory function or at the basal ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199910)42:4<631::aid-mrm3>
更新日期:1999-10-01 00:00:00
abstract::Keyhole acquisition techniques have been used to reduce image acquisition times primarily in contrast agent studies and via simulation in interventional MRI procedures. More recent simulations have suggested that improved definition of an interventional device [e.g., biopsy needles, radio frequency (RF) electrodes] co...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199909)42:3<554::aid-mrm18
更新日期:1999-09-01 00:00:00
abstract::The signals of water in the different compartments of rat sciatic nerve are resolved in the (2)H double-quantum-filtered NMR spectrum, due to their different quadrupolar splittings and relaxation rates. This resolution allowed the independent measurement of the water diffusion coefficients in the different compartment...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199909)42:3<461::aid-mrm8>
更新日期:1999-09-01 00:00:00
abstract::Two different types of (co-registered) images of the same slice of tissue will generally have different spatial resolutions. The judicious pixel-by-pixel combination of their data can be accomplished to yield a single image exhibiting properties of both. Here, axial (18)FDG PET and (1)H(2)O MR images of the human brai...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199908)42:2<345::aid-mrm17
更新日期:1999-08-01 00:00:00
abstract::MR images acquired by using an arterial spin-labeling technique showed spatial and temporal variations of perfusion in the skeletal muscle of exercising humans. Perfusion measurements made during plantar flexion exercise in normal volunteers were consistent with those obtained by traditional techniques reported in the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199908)42:2<258::aid-mrm7>
更新日期:1999-08-01 00:00:00
abstract::Magnetic resonance (MR) imaging and relaxation time measurements of bioresorbable implants made of polylactic acid (PLA), as well as the surrounding tissues, were carried out over a period of 6 months to monitor the implant state and the body's responses, and to determine how these processes are reflected in MR data. ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199907)42:1<210::aid-mrm29
更新日期:1999-07-01 00:00:00
abstract::Successful radiofrequency (RF) thermal ablation was performed on VX2 tumors implanted in 23 rabbit livers under magnetic resonance (MR) guidance using a C-arm-shaped low-field 0.2 T system. RF application and immediate postprocedure MRI of all animals was performed [T2-weighted, turbo short tau inversion recovery (STI...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199907)42:1<141::aid-mrm19
更新日期:1999-07-01 00:00:00
abstract::The water proton resonance frequency (PRF) is temperature dependent and can thus be used for magnetic resonance (MR) thermometry. Since lipid proton resonance frequencies do not depend on temperature, fat suppression is essential for PRF-based temperature mapping. The efficacy of echo-shifted (TE > TR) gradient-echo i...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199907)42:1<53::aid-mrm9>3
更新日期:1999-07-01 00:00:00
abstract::The rotating ultra-fast imaging sequence (RUFIS) is used to image spins flowing through the curved portion of a 180 degrees U-tube with a circular cross section and a ratio of inner diameter to curvature diameter of 0.41. A velocity-encoding preparation sequence is used with RUFIS to measure quantitatively the axial v...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199906)41:6<1258::aid-mrm2
更新日期:1999-06-01 00:00:00
abstract::It is demonstrated that birdcage resonators, satisfying conditions of quadrature operation and radiofrequency field homogeneity, can be realized in practice on formers of non-circular cross section described by an equation of the form (x/a)n + (y/b)n = 1 where a and b are constants and n > or = 2 is an integer. Using ...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199906)41:6<1180::aid-mrm1
更新日期:1999-06-01 00:00:00
abstract::An arterial spin labeling technique using separate RF labeling and imaging coils was used to obtain multislice perfusion images of the human brain at 3 T. Continuous RF irradiation at a peak power of 0.3 W was applied to the carotid arteries to adiabatically invert spins. Labeling was achieved without producing magnet...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199906)41:6<1093::aid-mrm4
更新日期:1999-06-01 00:00:00
abstract::Hyperpolarized (HP) 129Xe can be dissolved in biologically compatible lipid emulsions while maintaining sufficient polarization for in vivo vascular imaging. For xenon in Intralipid 30%, in vitro spectroscopy at 2 T yielded a chemical shift of 197 +/- 1 ppm with reference to xenon gas, a spin-lattice relaxation time T...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199905)41:5<1058::aid-mrm2
更新日期:1999-05-01 00:00:00
abstract::An automated retrospective image registration based on mutual information is adapted to a multislice functional magnetic resonance imaging (fMRI) acquisition protocol to provide accurate motion correction. Motion correction is performed by mapping each slice to an anatomic volume data set acquired in the same fMRI ses...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199905)41:5<964::aid-mrm16
更新日期:1999-05-01 00:00:00
abstract::Localized 1H NMR homonuclear J editing spectroscopy was used to measure the concentration of 2-pyrrolidinone (PRDN) in the human occipital lobe of five normal and six epileptic subjects taking vigabatrin. PRDN is a lactam cyclization product of gamma-aminobutyric acid (GABA). From a localized volume of 13.5 cm3 in the...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199905)41:5<889::aid-mrm6>
更新日期:1999-05-01 00:00:00
abstract::A simple theoretical model was developed to compare the sensitivities (i.e., signal-to-noise ratios per unit imaging time) of two-dimensional (2D) multislice and 3D imaging sequences. The model shows that the sensitivities of 3D and 2D multislice MRI sequences are usually similar. Sensitivities are identical in T2-wei...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199904)41:4<824::aid-mrm23
更新日期:1999-04-01 00:00:00
abstract::Tumor pH is physiologically important since it influences a number of processes relevant to tumorigenesis and therapy. Hence, knowledge of localized pH within tumors would contribute to understanding these processes. The destructiveness, poor spatial resolution, and poor signal-to-noise ratio (SNR) of current technolo...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199904)41:4<743::aid-mrm13
更新日期:1999-04-01 00:00:00
abstract::Human cardiac 31P nuclear magnetic resonance (NMR) spectra are usually quantified in relative terms, i.e., the ratio of metabolite signals is calculated. If 31P NMR spectroscopy of the heart is to emerge as a clinically relevant diagnostic modality, reliable quantification of absolute concentrations of 31P metabolites...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199904)41:4<657::aid-mrm3>
更新日期:1999-04-01 00:00:00
abstract::Wavelet packet analysis is a mathematical transformation that can be used to post-process images, for example, to remove image noise ("denoising"). At a very low signal-to-noise ratio (SNR <5), standard magnitude magnetic resonance images have skewed Rician noise statistics that degrade denoising performance. Since th...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199903)41:3<631::aid-mrm29
更新日期:1999-03-01 00:00:00
abstract::Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies p...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19
更新日期:1999-03-01 00:00:00
abstract::The time evolution of water diffusion, perfusion, T1, and T2 is investigated at high magnetic field (8.5 T) following permanent middle cerebral artery occlusion in the rat. Cerebral blood flow maps were obtained using arterial spin tagging. Although the quantitative perfusion measurements in ischemic tissue still pose...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199903)41:3<479::aid-mrm9>
更新日期:1999-03-01 00:00:00
abstract::Multislice, two-dimensional phosphorus 31 spectroscopic imaging (SI) of human brain was performed in 15 normal volunteers on a 3-Tesla magnetic resonance system. Images of free magnesium concentrations and pH as well as phosphoesters, inorganic phosphate, phosphocreatine, and adenosine triphosphate (ATP), were calcula...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199902)41:2<400::aid-mrm26
更新日期:1999-02-01 00:00:00
abstract::Focused ultrasound heating of ex vivo bovine kidney and liver was monitored using magnetic resonance imaging (MRI) to investigate the quantitative relationship between time-dependent temperature elevations and altered contrast in MR images due to thermal coagulation. Proton resonance frequency shift MR thermometry was...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199902)41:2<321::aid-mrm16
更新日期:1999-02-01 00:00:00
abstract::The role of relative cerebral blood volume (rCBV) in the early response of blood oxygenation level-dependent (BOLD) signal following sensory stimulation was assessed. Magnetic resonance imaging (MRI) measurements of rCBV and BOLD signal as a function of time (t) were compared with relative cerebral blood flow (rCBF) o...
journal_title:Magnetic resonance in medicine
pub_type: 杂志文章
doi:10.1002/(sici)1522-2594(199902)41:2<247::aid-mrm6>
更新日期:1999-02-01 00:00:00